Important
between the two connectors are defective. If you have an ASR that has a problem communicating with its
keypad/display board, you may want to verify continuity between the connectors on the digital board.
Turn off the power and unplug the 20-pin ribbon cable from the ASR digital board at J7 and the ASR 24-pin
display cable from the digital board at Jl. Using an ohmmeter, verify continuity between the following points
on the digital board:
57
(20~Din
connector)
J 1
(24-Din
connector)
Pin 1
to
Pin 9
Pin3 to Pin 10
Pin 5
to
Pin 11
TROUBLESHOOTING
Often the faulty module in an ASR can be determined through normal use. Sometimes, it is difficult to
isolate the problem. The following flowcharts can help you diagnose units that appear dead (no display).
When troubleshooting an ASR, always disconnect any expansion devices that may be present (such as the
SCSI Interface or OEX-6sr Output Expander). This will prevent a faulty expander from complicating your
troubleshooting. Remember, when you take out the SCSI board, connect the analog board to the digital
board via a 34 pin ribbon cable to J6 on the digital board and
Jl
on the analog board.
The following pages include troubleshooting information:
Pao,e
Problem
12
AC Line Voltages
13
Power Supply Voltage Check Points
14
ASR with Incorrect Analog Power Supply Voltages (flow chart)
15
ASR with Incorrect Digital Power Supply Voltages (flow chart)
16
Display Self-test Chart
17
ASR with No LEDs Lit (flow chart)
18
ASR with All LEDs Lit, No Display (flow chart)
19
ASR Foot Switch and Patch Select Inputs
20
ASR-88 Keyboard
ASR Service Manual